Mobile diesel generator set 0.4 kV, 82 (65.6)/kVA(kW) with an additional option of at least 48 hours of operation C90D5
| Engine. | Backup mode | Basic mode |
| Engine manufacturer | CUMMINS | |
| Engine model | 6BTA5.9 G5 | |
| Configuration | In-line; 6 cylinders | |
| Supercharging | Turbocharging and aftercooler | |
| Total output power, kW mech. | 102 | 93 |
| Average effective pressure at rated load, kPa | 1386 | 1265 |
| Cylinder diameter, mm | 102 | |
| Piston stroke, mm | 120 | |
| Rated speed, rpm | 1500 | |
| Piston movement speed, m/s | 6 | |
| Compression ratio | 17,6:1 | |
| Lubricant volume, l | 16,4 | |
| Maximum speed, rpm | 1800 | |
| Regenerative power, kW | 6,54 | |
| Type of regulator | Electronic | |
| Starting voltage | 12 V DC |
| Air. | Backup mode | Basic mode |
| Amount of air required for fuel combustion, l/sec | 7,86 | 7,2 |
| Max. resistance of the air filter, kPa | 6 | 6 |
Fuel system
| Maximum pressure in the fuel line, mm Hg | 8 |
| Max. temp. in the fuel line °C | 71 |
| Exhaust system | Backup mode | Basic mode |
| Exhaust gas volume at rated load, l/sec | 21,4 | 19,5 |
| Exhaust gas temperature, °C | 540 | 533 |
| Maximum back pressure, kPa | 10,2 | 10,2 |
| Radiator system | Backup mode | Basic mode |
| Estimated ambient temperature | 54 | 54 |
| Fan power, kWm. | 5,61 | 5,61 |
| Coolant volume (including radiator), l | 19,75 | 19,75 |
| Air flow through the cooling system, cubic meters per minute at 12.7 mm | 3,44 | 3,44 |
| Total heat output, Btu/min | 9259 | 8419 |
| Maximum static resistance to air flow, mm H2O | 12,7 | 12,7 |
| Weight | Closed type |
| Dry weight of the unit, kg | 1879 |
| Total weight of the installation, kg | 2713 |
| Fuel tank capacity, l | 830 |
| Dimensions | Length. | Width | Height |
| Under the hood (excluding muffler) | 3166 | 1100 | 2212 |
Alternator
| Manufacturer | STAMFORD |
| Model. | UCI224G |
| Type | Brushless, single-bearing, with explicit pole rotor |
| Stator | 2/3 step winding |
| Rotor | Single bearing with flexible disk coupling |
| Insulation system | H |
| Standard temperature rise | Backup mode 50 Hz – 163ºC/27ºC |
| Type of excitation | Self-excited |
| Alternation of phases | A (U), B (V), C (W) |
| Alternator cooling | Centrifugal fan with direct drive |
| Total Harmonic Distortion Value (THDV) | Idling <1.5%. Undistorted balanced linear load <5%. |
Alternator power
| Class – Max. temp. | Constant, F – 105/40°C | Constant, H – 125/40°C | |||||||
| Phase / star (V) | 380 | 400 | 415 | 440 | 380 | 400 | 415 | 440 | |
| Parallel / star (V) | 190 | 200 | 208 | 220 | 190 | 200 | 208 | 220 | |
| Phase / delta (V) | 220 | 230 | 240 | 254 | 220 | 230 | 240 | 254 | |
| 50 Hz | kVA | 75.0 | 75.0 | 75.0 | 67.4 | 85.0 | 85.0 | 85.0 | 75.0 |
| kW | 60.0 | 60.0 | 60.0 | 53.9 | 68.0 | 68.0 | 68.0 | 60.0 | |
| EFFICIENCY %. | 90.3 | 90.6 | 90.7 | 91.0 | 89.8 | 90.2 | 90.4 | 90.9 | |
| Input power, kW | 66.4 | 66.2 | 66.2 | 59.2 | 75.7 | 75.4 | 75.2 | 66.0 |